MG5 exchanges the contactor (reach the company to examine fast by Switzerland)
Use: Use for and exchange 50Hz mainly, specified voltage to 660 V, electric current put through and divide and break the circuit to 40 power system of A.
Technical data: 1.Insulating voltage of amount: Main circuit 660V, assists Circuit 500V;
2.Amount controls the voltage of the power : Direct current 80V, can Voltage per shelf of alternating and direct current according to user's enquiry;
3.Mainly touch rated power 380V of head, 20KW, assist Auxiliary contact 760VA, 2 make contact , 2 break contact.
Durability: 15 million times Machankal Durability, Electrical Durability 650,000 times.
MG6 exchanges the contactor (reach the company to examine fast by Switzerland)
Use: Use for and exchange 50Hz mainly, specified voltage to 660 V, electric current put through and divide and break the circuit to 40 power system of A.
Technical data: 1.Insulating voltage of amount: Main circuit 660V, assists Circuit 500V;
2.Amount controls the voltage of the power : Direct current 80V, can Voltage per shelf of alternating and direct current according to user's enquiry;
3.Mainly touch rated power 380V of head, 20KW, assist Auxiliary contact 760VA, 2 make contact , 2 break contact.
Durability: 15 million times Machankal Durability, Electrical Durability 650,000 times.
MRG62 auxiliary contactor
Use: Used for exchanging 50Hz mainly, voltage 380V, the direct current presses to 110 V control circuit to increase the intensity of signal the quantity .
Technical data: 1.Insulating voltage 380V of amount;
2.Amount controls the voltage of the power ; 80V, 48V,etc.;
3.Touch the head and control the capacity: Direct current 60W, exchanges 300VA. 4 make contact , 4 break contact 6 make contact , 1 break contact
Durability: 10 million times Machankal Durability, Electrical Durability 1 million times.
CFZ1 auxiliary contactor (reach the company to examine fast by Switzerland)
Use: Used for exchanging 50Hz mainly, the specified voltage increases the intensity of signal and quantity and transmit and give and control the component at the same time to 380 V
Technical data: 1.Insulating voltage 380V of amount;
2.Amount controls voltage 80V of the power, 22V,etc.;
3.Touch the head and control the capacity: Exchange 150VA, direct current 50W. 2 make contact , 2 break contact 3 make contact , 1 break contact
Durability: 10 million times Machankal Durability, Electrical Durability 1 million times.
PFR owes the electric apparatus in succession
Use: The protecting scarcly of three-phase power.
Technical data: 1.Input the voltage three phases and exchange voltage 160 V-242Vs;
2.Voltage of movement: Above voltage difference 42V of space;
3.Not the voltage of movement: Within voltage difference 15V of space;
4.Movement time: <= 1.5S; 5.Reduce time: <= 1.5S.
PFR electric apparatus in succession instead
Use: Prevent the three-phase power looks preface from connecting inside out.
Technical data: 1.Input the voltage three phases and exchange voltage 160 V-242Vs;
2.Voltage of movement: When the looks preface is opposite;
3.Not the voltage of movement: Voltage difference of space hour of the straight preface
   Within 15V; 4.Movement time: <= 0.1S.
Stand that XL series insure
Use: Unless suitable for this product it exchange 50Hz of, from voltage to 220 V,ones that protect circuit of under 10 A with (appearance manage Ø 6.4 x30 mm insurance)
Type Size of appearance Install the aperture Remarks
XL-1 13.5x48x23 Ø4.5 Can have excellent choices according to user's enquiry .
XL-2 24.5x48x23 Ø4.5
XL-5 57.5x48x23 Ø4.5
XL-10 112.5x48x23 Ø4.5
Return